THE USE OF TEST ROOMS TO DETERMINE THE THERMAL PERFORMANCE OF A TRANSPARENTLY INSULATED OPAQUE WALL

Citation
Pr. Dolley et al., THE USE OF TEST ROOMS TO DETERMINE THE THERMAL PERFORMANCE OF A TRANSPARENTLY INSULATED OPAQUE WALL, Building and environment, 28(2), 1993, pp. 139-143
Citations number
NO
Categorie Soggetti
Construcion & Building Technology
Journal title
ISSN journal
03601323
Volume
28
Issue
2
Year of publication
1993
Pages
139 - 143
Database
ISI
SICI code
0360-1323(1993)28:2<139:TUOTRT>2.0.ZU;2-H
Abstract
A side by side comparison between a test room equipped with an opaque wall clad with a proprietary polycarbonate, honeycomb transparent insu lation material (TIM) and a reference room is described. The measured data are analysed in terms of straight forward comparisons between the energy consumptions of wall heat fluxes in the two rooms. The results are parameterized by a steady state specific heat loss (U-value: air to air) and a solar collection efficiency (epsilon) for the wall. Usin g these values the performance is extrapolated to a whole year under U .K. climate.