ADVANCED GLAZING - OUTDOOR TEST ROOM MEASUREMENTS, PERFORMANCE PREDICTION AND BUILDING THERMAL SIMULATION

Citation
P. Robinson et J. Littler, ADVANCED GLAZING - OUTDOOR TEST ROOM MEASUREMENTS, PERFORMANCE PREDICTION AND BUILDING THERMAL SIMULATION, Building and environment, 28(2), 1993, pp. 145-152
Citations number
NO
Categorie Soggetti
Construcion & Building Technology
Journal title
ISSN journal
03601323
Volume
28
Issue
2
Year of publication
1993
Pages
145 - 152
Database
ISI
SICI code
0360-1323(1993)28:2<145:AG-OTR>2.0.ZU;2-C
Abstract
Methods of assessing the thermal performance of advanced glazing syste ms by measurement in the MoWiTT test rooms and by prediction with the WINDOW glazing simulation package are described. The glazing treatment of a whole building simulation model, SERI-RES, is outlined and the l imitations highlighted. Results are presented of measurements made on an advanced glazing system in the test rooms and compared with WINDOW predictions, driven with weather data recorded during the MoWiTT tests . In the light of this comparison a recommendation is made to use WIND OW as a pre-processor for SERI-RES to aid more accurate representation of advanced glazing systems.