K. Randow et T. Derand, ON FUNCTIONAL STRAIN IN SOME FIXED AND REMOVABLE PARTIAL DENTURES - AN EXPERIMENTAL INVITRO STUDY, Acta Odontologica Scandinavica, 51(3), 1993, pp. 153-159
An 11-unit fixed maxillary reconstruction with 2 bilateral cantilever
pontics in combination with a removable partial denture (RPD) with a p
alatal bar was fabricated. The RPD was retained to the fixed reconstru
ction with precision attachments. A laboratory model system was constr
ucted in such a manner that the mechanical properties of the biologic
supporting tissues involved were simulated by artificial materials. By
means of a strain-gauge technique the deformation was studied in both
the fixed and the removable partial denture. In different laboratory
loading situations with and without the RPD the deformation in the fix
ed dental appliance was more extensive and more complex when the RPD w
as excluded.