A sandwich-type enzyme immunoassay for tenascin (TN) was established b
y the use of two anti-human TN monoclonal antibodies and human TN prod
uced by human melanoma cells as a standard. The assay system consists
of polystyrene balls (6.5 mm in diameter) with immobilized first monoc
lonal antibody F(ab')2 fragments and the other antibody F(ab')2 fragme
nts labeled with beta-D-galactosidase from Escherichia coli. The assay
system has a minimum detectable sensitivity of 2 ng per assay tube, b
eing sufficiently sensitive for the determination of serum TN concentr
ations with a satisfactory precision. Serum TN concentrations of healt
hy subjects were less than 2.0 mg per liter (n=29, mean +/- SD, 0.897
+/- 0.250 mg per liter) and those in sera of some patients with carcin
oma were enhanced (n=47, mean +/- SD, 2.546 +/- 1.746 mg per liter).