J. Wirta et al., REVISION OF CEMENTED HIP ARTHROPLASTIES - 101 HIPS FOLLOWED FOR 5 (4-9) YEARS, Acta orthopaedica Scandinavica, 64(3), 1993, pp. 263-267
101 hips were revised with cemented Lubinus prostheses after failed pr
imary cemented arthroplasty, and followed for 5 (4-9) years. Radiograp
hically, 41 hips (36 femoral stems and 13 acetabular components) had b
ecome loose. The use of an intramedullary plug at the revision did not
prevent sinking of the prosthesis. No difference was found between co
nventional or pressure-injection cementation techniques. In cases wher
e the stem was inserted in varus or the acetabular component was in ma
lposition there was increased loosening. Patients below 50 years of ag
e had oftener more than 5 mm sinking of the stem and more prosthesis l
oosenings.