A. Siriraks et al., IMPROVED METHOD FOR THE DETERMINATION OF MANGANESE IN NUCLEAR-POWER-PLANT WATERS, Journal of chromatography, 640(1-2), 1993, pp. 371-378
An improved method for manganese deterMination in nuclear power plant
waters has been developed. This method combines a selective chelation
concentration method with a unique analytical separation for manganese
from the interfering matrix using a weak acid cation exchange column.
The detection sensitivity by conventional post-column derivatization
is improved with the combination of chemical eluent suppression and su
bsequent post-column derivatization. The detection limit for manganese
in ammonium matrix is approximately 2 pg/ml and the limit of quantita
tion 10 pg/ml with 100 ml sample volume.