SOLVENT-EXTRACTION AND SENSITIVE ONE-DROPFLAME ATOMIC-ABSORPTION SPECTROMETRIC DETERMINATION OF LEACHABLE LEAD FROM LEAD-GLAZED CERAMICWARE
Citation
I. Kojima et A. Suzuki, SOLVENT-EXTRACTION AND SENSITIVE ONE-DROPFLAME ATOMIC-ABSORPTION SPECTROMETRIC DETERMINATION OF LEACHABLE LEAD FROM LEAD-GLAZED CERAMICWARE, Bunseki Kagaku, 42(7), 1993, pp. 435-437
Categorie Soggetti
Chemistry Analytical
SICI code
0525-1931(1993)42:7<435:SASOAS>2.0.ZU;2-7
Abstract
Low concentrations of lead leached from lead-glazed ceramicware into 4
% acetic acid were determined by the one-drop atomic absorption spectr
ometry with a fuel-lean air-acetylene flame after the extraction of le
ad pyrrolidin-1-yldithioformate into chloroform. To a glass test tube
with a stopper, 5 ml (or 10 ml) of 4% acetic acid leachate and 1 ml (o
r 2 ml) of 1 % ammonium pyrrolidinedithiocarbamate solution were taken
and the mixture was shaken with 0.5 ml of chloroform 3 times for 10 s
by hand. Direct nebulization of 50 mul of the chloroform extract of l
ead complex gave a 3.9 times more sensitive signal height than that ob
tained by nebulizing a 4% acetic acid solution. With this technique, l
ead at 0.1 mug/ml levels in 4% acetic acid was easily determined witho
ut background correction. This method was very simple and gave very go
od reproducibility (RSD = 1.4 % at 3 mug/ml chloroform).