PRECONCENTRATION AND DETERMINATION OF TRACE HEXAVALENT CHROMIUM[CR(VI)] IN WATER SAMPLES BY PRECIPITATE FLOTATION

Citation
Ys. Kim et al., PRECONCENTRATION AND DETERMINATION OF TRACE HEXAVALENT CHROMIUM[CR(VI)] IN WATER SAMPLES BY PRECIPITATE FLOTATION, Bulletin of the Korean Chemical Society, 14(3), 1993, pp. 330-335
Citations number
22
Categorie Soggetti
Chemistry
ISSN journal
02532964
Volume
14
Issue
3
Year of publication
1993
Pages
330 - 335
Database
ISI
SICI code
0253-2964(1993)14:3<330:PADOTH>2.0.ZU;2-G
Abstract
The separative preconcentration of trace Cr(VI) in a water sample was studied by a precipitate flotation technique. After Cr(III), Al, Mg, a nd organic materials were removed by the pre-flotation with Fe(OH)3, t race Cr(VI) in 1.0 L of water sample was coprecipitated by the precipi tation of AgCl in the solution of pH 8-9 adjusted with NaHCO3. All pre cipitates were floated by adding mixed surfactants, 1 : 1 solution of 0.5% sodium oleate and 0.5% sodium dodecyl sulfate ehtanolic solutions , and bubbling nitrogen gas. The floats were quantitatively collected on a micropore glass filter by suction and dissolved with conc. ammoni a solution. The solution was marked to 25.00 mL with distilled water. Cr(VI) was determined by graphite furnace atomic absorption spectropho tometry. The results for seven determinations of one sample showed rel atively good reproducibility with relative standard deviation of 9.71% . Recoveries were 86.0 and 91.0% for sample solutions in which 0.5 and 1.0 ng/mL Cr(VI) were spiked, respectively. The detection limit was i mproved about 20 times by this method.