An expression is derived for the threshold sensitivity theta of an aco
ustic thermometer, and the characteristics of the instrument that gove
rn the threshold-the noise temperature T(n) and the smoothing factor Q
-are determined for arbitrary parameters of the receiving piezoelectri
c transducer, rf amplifier, and low-pass filter and with allowance for
the internal noise of the instrument.