We report a case in which an intraocular lens dislocated entirely with
in the capsular bag. The patient was myopic with a large anterior segm
ent. A standard 5 mm x 6 mm phaco profile intraocular lens was found t
o be completely dislocated on the fifth postoperative day. The disloca
ted lens was replaced with another posterior chamber intraocular lens
sutured at the ciliary sulcus.