A. Tuunainen et U. Nousiainen, ICTAL RECORDINGS OF AMBULATORY CASSETTE EEG WITH SPHENOIDAL ELECTRODES IN TEMPORAL-LOBE EPILEPSY - COMPARISON WITH INTENSIVE VIDEO MONITORING, Acta neurologica Scandinavica, 88(1), 1993, pp. 21-25
Seventy-three seizures in 18 epilepsy patients were studied by analyzi
ng the ictal findings of 8-channel ambulatory EEG (A/EEG) and adjacent
16-channel intensive videomonitoring (IVM). With IVM and A/EEG analys
is, accuracy was excellent for determining the lateralization of seizu
re progression; whereas at seizure onset and post-ictal slowing, accur
acy was poor. No false lateralization was found in A/EEG compared with
IVM or lateralization according to patient data, and in seizure later
alization the interpretation of A/EEG was discordant in only 3 seizure
s with IVM analysis. According to our study, ictal 8-channel A/EEG wit
h sphenoidal electrodes is not suitable for localization of temporal l
obe foci, but is reliable for lateralization analysis.