Abstract
The purpose of this study was to determine the influence of the surgeo n's tying technique on knot security using 0 and 2-0 monofilament and multifilament nylon sutures. Using an Instron(R) Tensile Tester and a portable tensiometer, knot security was achieved with these sutures us ing four-throw square knots (1=1=1=1). After didactic and psychomotor skill training, medical students were taught to construct the four-thr ow square knot using either a two-hand tie or an instrument tie. Using the portable tensiometer, their knot tying techniques were judged to be superior to those used by surgeons. The surgeon's faulty technique can easily be corrected by didactic information and psychomotor skill training. (C) 1993 John Wiley & Sons, Inc.