H. Takamatsu et al., A CORRELATION FOR FORCED CONVECTIVE BOILING HEAT-TRANSFER OF NONAZEOTROPIC REFRIGERANT MIXTURE OF HCFC22 CFC114 IN A HORIZONTAL SMOOTH TUBE/, International journal of heat and mass transfer, 36(14), 1993, pp. 3555-3563
Experiments are carried out on the boiling heat transfer of nonazeotro
pic refrigerant mixtures of HCFC22/CFC114 flowing inside a 7.9 mm ID h
orizontal smooth tube. Using a water-heated, double-tube type evaporat
or. the local heat transfer coefficients are measured for both counter
and parallel flows. An empirical correlation equation is proposed for
the data in the annular-flow regime, taking into account the mixture
effect in the authors' previous correlation equation for pure refriger
ants. The mean deviation between the calculated and measured heat tran
sfer coefficients is 8.9% for the present experimental data and 7.1% f
or the data obtained by Jung. The equation reveals that the convection
heat transfer is dominant due to the suppression of nucleate boiling
for the mixtures.