We studied 43 patients with ipsilateral femoral shaft and femoral neck
fractures who had dynamic hip screw fixation alone or in combination
with dynamic compression plate. All patients except two were diagnosed
early; 37 patients had other associated injuries. There were 41 males
and two females. The follow-up ranged from eight months to four years
(mean 2-1/2 years). Six patients were lost to follow-up. Fracture of
the neck of the femur healed in all 37 patients. Four patients had del
ayed union and two patients developed nonunion of the shaft of the fem
ur. The aim of this paper is to show our experience and results using
one technique for the treatment of such fractures.