PCDD/F concentration in deposition and in ambient air was measured at
different locations in the state of Baden-Wurttemberg, Germany. The av
erage dioxin concentration in particulate deposition ranged from 5 to
36 pg I-TEQ/m(2)d, while the ambient air concentration ranged from 14
to 77 fg I-TEQ/m(3). In addition, particulate depositions (mg/m(2)d),
calculated PCDD/F concentration in particulate depositions (ng I-TEQ/k
g), suspended particles (< 10 mu m) in air (mu g/m(3)) and the calcula
ted PCDD/F concentration in suspended particulate matter (ng I-TEQ/kg)
are reported. Rural areas and urban areas differ in PCDD/F pollution.
Connections of PCDD/F concentration vs, temperature, PCDD/F concentra
tion in grass vs. deposition and PCDD/F concentration in deposition vs
. rainfall have been measured. The rural area in elevated exposition (
Black Forest) reflects the influence of weather and long range transpo
rt. (C) 1997 Elsevier Science Ltd.