2ND-GENERATION LOW-EMISSION COMBUSTORS FOR ABB GAS-TURBINES - FIELD-MEASUREMENTS WITH GT11N-EV

Authors
Citation
M. Aigner et G. Muller, 2ND-GENERATION LOW-EMISSION COMBUSTORS FOR ABB GAS-TURBINES - FIELD-MEASUREMENTS WITH GT11N-EV, Journal of engineering for gas turbines and power, 115(3), 1993, pp. 533-536
Citations number
3
Categorie Soggetti
Engineering, Mechanical
ISSN journal
07424795
Volume
115
Issue
3
Year of publication
1993
Pages
533 - 536
Database
ISI
SICI code
0742-4795(1993)115:3<533:2LCFAG>2.0.ZU;2-5
Abstract
In February 1991, a type GT11N gas turbine (Midland, USA) was retrofit ted with ABB's new EV-Silo-Combustor. Tests were then carried out to e xamine the operation concept, to demonstrate the technical reliability , and to confirm the low emission performance of this new technology. This paper will describe: the combustor design-one single silo combust or mounted on the turbine and equipped with 37 Ev burners, and the res ults of the extensive field measurements-the operation concept (lean p remix combustion without any pilot diffusion flames, 7 burner groups) is simple and reliable. The emission targets-NO(x) < 2.5 ppmv (15 perc ent O2, natural gas), CO < 8 ppmv, UHC<5 ppmv-were reached. NO(x) valu es are even lower than 15 ppmv at base load. The NO(x) predictions for the GT11N-EV, based on the results of high-pressure tests in Cologne (ASME Paper No. 90-GT-308), compared very well with the results of fie ld measurements.