SECONDARY STANDARD FOR PM AND AM NOISE AT 5, 10, AND 100 MHZ

Authors
Citation
Fl. Walls, SECONDARY STANDARD FOR PM AND AM NOISE AT 5, 10, AND 100 MHZ, IEEE transactions on instrumentation and measurement, 42(2), 1993, pp. 136-143
Citations number
13
Categorie Soggetti
Engineering, Eletrical & Electronic","Instument & Instrumentation
ISSN journal
00189456
Volume
42
Issue
2
Year of publication
1993
Pages
136 - 143
Database
ISI
SICI code
0018-9456(1993)42:2<136:SSFPAA>2.0.ZU;2-1
Abstract
This paper describes a practical implementation of a portable secondar y standard for phase modulation (PM) and amplitude modulation (AM) noi se at 5, 10, and 100 MHz. The accuracy of the standard for both PM and AM noise is +0.14 dB, and the temperature coefficient is less than 0. 02 dB/K. The noise floor S(phi)(10 kHz) of the standard for PM noise m easurements is less than -190 dBC relative to 1 rad2/Hz at 5, 10, and 100 MHz. The noise floor for AM measurements depends on the configurat ion. A calibrated level of PM and AM noise of approximately -130 +/- 0 .2 dB relative to 1 rad2/HZ (for Fourier frequencies from approximatel y 1 Hz to 10% of the carrier frequency) is used to evaluate the accura cy versus Fourier frequency. Similar PM/AM noise standards are under t est at 10 GHz. This new standard can also be used as an alternative to the normal method of calibrating the conversion sensitivity of the PM /AM detector for PM/AM measurements. Some types of time-domain measure ment equipment can also be calibrated.