A 10-V CALIBRATING SYSTEM USING AN AUTOMATED VOLTAGE DIVIDER AND A 1-V JOSEPHSON ARRAY

Citation
Y. Sakamoto et al., A 10-V CALIBRATING SYSTEM USING AN AUTOMATED VOLTAGE DIVIDER AND A 1-V JOSEPHSON ARRAY, IEEE transactions on instrumentation and measurement, 42(2), 1993, pp. 583-587
Citations number
8
Categorie Soggetti
Engineering, Eletrical & Electronic","Instument & Instrumentation
ISSN journal
00189456
Volume
42
Issue
2
Year of publication
1993
Pages
583 - 587
Database
ISI
SICI code
0018-9456(1993)42:2<583:A1CSUA>2.0.ZU;2-L
Abstract
A 10 V calibrating system has been developed by combining an automated voltage divider and a 1 V Josephson junction array voltage standard. The system can calibrate the 10 V output of a Zener voltage reference with an uncertainty of 0.02 ppm.