LATE EXTRUSION OF ALLOPLASTIC ORBITAL FLOOR IMPLANTS

Authors
Citation
Ae. Brown et P. Banks, LATE EXTRUSION OF ALLOPLASTIC ORBITAL FLOOR IMPLANTS, British journal of oral & maxillofacial surgery, 31(3), 1993, pp. 154-157
Citations number
18
Categorie Soggetti
Dentistry,Oral Surgery & Medicine
ISSN journal
02664356
Volume
31
Issue
3
Year of publication
1993
Pages
154 - 157
Database
ISI
SICI code
0266-4356(1993)31:3<154:LEOAOF>2.0.ZU;2-U
Abstract
Complications following the use of alloplastic orbital floor implants are well documented but it is not widely recognised that these can occ ur many years after initial treatment. Three patients who presented wi th late extrusion of an implant through the facial skin are reported. This complication occurred 10, 16 and 17 years respectively after trea tment of the orbital floor fracture. The tissue reaction to silicone r ubber and Teflon inplants is reviewed and the possible cause for this late complication is discussed.