CORRELATION BETWEEN ELECTRICAL-CONDUCTION AND MICRODROP SIZE DISTRIBUTION IN THE OCTANE WATER SODIUM DODECYL-SULFATE PENTANOL SYSTEM

Citation
Av. Sineva et Ve. Smorodin, CORRELATION BETWEEN ELECTRICAL-CONDUCTION AND MICRODROP SIZE DISTRIBUTION IN THE OCTANE WATER SODIUM DODECYL-SULFATE PENTANOL SYSTEM, Colloid journal of the Russian Academy of Sciences, 54(5), 1992, pp. 745-748
Citations number
7
Categorie Soggetti
Chemistry Physical
ISSN journal
1061933X
Volume
54
Issue
5
Year of publication
1992
Pages
745 - 748
Database
ISI
SICI code
1061-933X(1992)54:5<745:CBEAMS>2.0.ZU;2-U
Abstract
The phase (structural) transitions in the octane-water-sodium dodecyl sulfate-pentanol system were investigated. The average hydrodynamic an d most probable (effective) microdrop sizes were found in a wide range of values of the volume fraction of water PHI (from 0.02 to 0.83) by photon correlation spectroscopy. The applicability of the cell model f or describing the specific conduction as a function of the effective m icrodrop size in the region of low PHI above the conduction percolatio n threshold was established.