A. Bejan et al., THE COOLING OF A HEAT-GENERATING BOARD INSIDE A PARALLEL-PLATE CHANNEL, International journal of heat and fluid flow, 14(2), 1993, pp. 170-176
This paper addresses the fundamental question of how to position a hea
t-generating board inside a parallel-plate channel, where it is cooled
by forced convection. It is shown that when the board substrate is a
relatively good thermal conductor, the best board position is near one
of the channel walls, and the worst position is in the middle of the
channel. The best and worst positions switch places when the board sub
strate is a relatively poor conductor. The optimal spacing between a h
eat-generating surface (uniform temperature, or uniform heat flux) and
the insulated wall that completes a parallel-plate channel is reporte
d. Finally, it is shown under what conditions it is advantageous to di
vide a heat-generating board into two or more equidistant boards insid
e the same channel, when the total rate of heat generation of all the
boards and the channel spacing are fixed.