DESIGN PARAMETERS OF A NON-AIR-CONDITIONED CINEMA HALL FOR THERMAL COMFORT UNDER ARID-ZONE CLIMATIC CONDITIONS

Citation
Gn. Tiwari et al., DESIGN PARAMETERS OF A NON-AIR-CONDITIONED CINEMA HALL FOR THERMAL COMFORT UNDER ARID-ZONE CLIMATIC CONDITIONS, Energy and buildings, 19(4), 1993, pp. 249-261
Citations number
NO
Categorie Soggetti
Energy & Fuels","Construcion & Building Technology
Journal title
ISSN journal
03787788
Volume
19
Issue
4
Year of publication
1993
Pages
249 - 261
Database
ISI
SICI code
0378-7788(1993)19:4<249:DPOANC>2.0.ZU;2-C
Abstract
In this communication, a design of a cinema hall suitable for climatic conditions in an arid zone has been presented. The various cooling te chniques, namely evaporative cooling, wind tower, ventilation/infiltra tion and natural cooling, have been incorporated in the design to achi eve thermal comfort during the period of operation. The design paramet ers have been optimized on the basis of numerical computations after e stablishing an energy balance for each component of a cinema hall. It is observed that cooling treatment, i.e., a wind tower with a cooling pool on the roof provides reasonable thermal comfort inside the enclos ure.