J. Jager et al., PRACTICAL CONCEPTS TO MINIMIZE THE EMISSION OF HALOGENATED ORGANIC-COMPOUNDS FROM MUNICIPAL SOLID-WASTE INCINERATORS, Chemosphere, 27(1-3), 1993, pp. 141-148
The authors present their research findings at four different municipa
l waste incinerators (MWIs) concerning generation and release of dioxi
ns and furans. The analytical results of the following design and oper
ation conditions are described: 'cold blowing'', flue gas cooling and
'soot blowing''. In addition, input variation test results are present
ed. Consequences for reducing the emission of halogenated dioxins and
furans are discussed.