G. Ranucci et al., PERFORMANCES OF THE PHOTOMULTIPLIER EMI-9351 FOR UNDERGROUND PHYSICS APPLICATIONS, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 333(2-3), 1993, pp. 553-559
In this article we discuss the results of tests performed on the 8 in.
EMI 9351 photube. The measurements were mainly devoted to evaluate pu
lse height and time resolution of the tube after single photon illumin
ation. The impact of small magnetic fields on these parameters was als
o carefully investigated.