TECHNICAL NOTE - COMPUTED TOMOGRAPHIC DACRYOCYSTOGRAPHY

Citation
Dw. Waite et al., TECHNICAL NOTE - COMPUTED TOMOGRAPHIC DACRYOCYSTOGRAPHY, British journal of radiology, 66(788), 1993, pp. 711-713
Citations number
8
Categorie Soggetti
Radiology,Nuclear Medicine & Medical Imaging
Journal title
British journal of radiology
ISSN journal
00071285 → ACNP
Volume
66
Issue
788
Year of publication
1993
Pages
711 - 713
Database
ISI
SICI code
Abstract
The technique of computed tomographic dacryocystography is described. It was developed in response to the pre-operative imaging requirements for transnasal endoscopic dacryocystorhinostomy, a new minimally inva sive operation performed as a primary procedure to relieve epiphora. H owever, it is also helpful in the assessment of patients after failed conventional external dacryocystorhinostomy when the information provi ded will help to determine the subsequent surgical approach. In additi on the technique will assist surgical planning in cases of epiphora as sociated with sinus surgery, facial trauma and maxillofacial tumours b y determining the site and extent of pathology.