Fundamental parameters of acoustic thermometers (AT) with a piezotrans
ducer (PT) without coupling layers and with a quarter-wavelength coupl
ing layer, i.e., the noise temperature T(n) and the equivalent transmi
ssion band DELTAf(e) and also the value of AT threshold sensitivity th
eta determined by them, are found out in the basis of data obtained in
Ref. 4. Taking into account real values of AT parameters (losses in P
T without a quarter-wavelength coupling layer, high frequency amplifie
r noise, utilization of a modulator and a square-law detector) the cal
culated value of theta is about 0.4 K, which is considerably higher th
an the value of theta = 0.05 K obtained in Ref. 2 without taking accou
nt of these parameters. The value of theta can be reduced to 0.1 K for
PT with a quarter-wavelength coupling layer.