DETERMINATION OF COPPER BY ANODIC-STRIPPING VOLTAMMETRY ON A GLASSY-CARBON ELECTRODE USING A CONTINUOUS-FLOW SYSTEM

Citation
Jf. Vanstaden et M. Matoetoe, DETERMINATION OF COPPER BY ANODIC-STRIPPING VOLTAMMETRY ON A GLASSY-CARBON ELECTRODE USING A CONTINUOUS-FLOW SYSTEM, Fresenius' journal of analytical chemistry, 357(6), 1997, pp. 624-628
Citations number
13
Categorie Soggetti
Chemistry Analytical
ISSN journal
09370633
Volume
357
Issue
6
Year of publication
1997
Pages
624 - 628
Database
ISI
SICI code
0937-0633(1997)357:6<624:DOCBAV>2.0.ZU;2-J
Abstract
A successful flow-through system was developed for trace analysis of c opper using DPASV with a glassy-carbon electrode. Periodical chemical regeneration of the electrode with a 1 mol/L NaOH solution increased s ensitivity and precision. The method was shown to be applicable with a detection limit of 0.56 mu g/L, with a determination time of less tha n 7 min per measurement (without deaeration time). The draw-back of th e system is the 10 min deaeration time. The system gave an accuracy of 0.090 +/- 0.005% for a certified reference material of low alloy stee l containing 0.090 +/- 0.004% Cu. Applicability to various fresh water samples with a Cu content between 1.57 and 13.11 mu g/L with an RSD < 2.36% is illustrated.