INJURIES ASSOCIATED WITH THE USE OF A LINEAR STAPLER DURING OPERATIVELAPAROSCOPY - REVIEW OF DIAGNOSIS, MANAGEMENT, AND PREVENTION

Citation
C. Nezhat et al., INJURIES ASSOCIATED WITH THE USE OF A LINEAR STAPLER DURING OPERATIVELAPAROSCOPY - REVIEW OF DIAGNOSIS, MANAGEMENT, AND PREVENTION, Journal of gynecologic surgery, 9(3), 1993, pp. 145-150
Citations number
10
Categorie Soggetti
Obsetric & Gynecology
ISSN journal
10424067
Volume
9
Issue
3
Year of publication
1993
Pages
145 - 150
Database
ISI
SICI code
1042-4067(1993)9:3<145:IAWTUO>2.0.ZU;2-B
Abstract
We report 7 recent examples of intraoperative and postoperative compli cations and injuries resulting from the use of an automatic stapling d evice during operative laparoscopy. The cases were collected throughou t the United States and represent a cross-section of common complicati ons. This report should alert surgeons to the possibilities of uretera l, bladder, and bowel injuries, postoperative bleeding, and instrument malfunctions. In addition, precautions and techniques to prevent and resolve complications are discussed.