RETROFITTING RECIPROCATING-COMPRESSORS FOR NOISE-CONTROL

Authors
Citation
L. Frank et R. Quaife, RETROFITTING RECIPROCATING-COMPRESSORS FOR NOISE-CONTROL, Journal of Canadian Petroleum Technology, 32(8), 1993, pp. 55-60
Citations number
NO
Categorie Soggetti
Energy & Fuels","Engineering, Chemical
ISSN journal
00219487
Volume
32
Issue
8
Year of publication
1993
Pages
55 - 60
Database
ISI
SICI code
0021-9487(1993)32:8<55:RRFN>2.0.ZU;2-F
Abstract
Industrial noise has caused environmental noise pollution from many oi l and gas facilities. The Alberta Energy Resources Conservation Board (ERCB) has enacted legislation to control excessive noise, which has c aused facilities to mitigate their operations. This paper presents a d escriptive case study of how an Alberta gas processing facility reduce d the amount of environmental noise it generated. by first assessing w hich plant equipment was responsible for the louder noise generation. and then by designing a balanced acoustical silencer retrofit program. The result was a significant noise reduction that met the ERCB requir ements.