Closed-loop performance monitoring in the presence of system changes and disturbances

Citation
F. Gustafsson et Sf. Graebe, Closed-loop performance monitoring in the presence of system changes and disturbances, AUTOMATICA, 34(11), 1998, pp. 1311-1326
Citations number
20
Categorie Soggetti
AI Robotics and Automatic Control
Journal title
AUTOMATICA
ISSN journal
00051098 → ACNP
Volume
34
Issue
11
Year of publication
1998
Pages
1311 - 1326
Database
ISI
SICI code
0005-1098(199811)34:11<1311:CPMITP>2.0.ZU;2-L
Abstract
This paper addresses issues in closed-loop performance monitoring. Particul ar attention is paid to detecting whether an observed deviation from nomina l performance is due to a disturbance or due to a control relevant system c hange. This is achieved by introducing a novel performance measure that all ows feasible application of a standard CUSUM change detector. The paper inc ludes explicit results on the risk of mistaking a disturbance for a system change. The algorithm has been implemented in real time on a DSP and evalua ted on a DC motor. (C) 1998 Elsevier Science Ltd. All rights reserved.