Determination of apramycin in swine kidney tissue by liquid chromatographywith fluorescence detection

Citation
Dj. Sweeney et Mr. Coleman, Determination of apramycin in swine kidney tissue by liquid chromatographywith fluorescence detection, J AOAC INT, 81(6), 1998, pp. 1141-1145
Citations number
11
Categorie Soggetti
Agricultural Chemistry
Journal title
JOURNAL OF AOAC INTERNATIONAL
ISSN journal
10603271 → ACNP
Volume
81
Issue
6
Year of publication
1998
Pages
1141 - 1145
Database
ISI
SICI code
1060-3271(199811/12)81:6<1141:DOAISK>2.0.ZU;2-4
Abstract
A liquid chromatographic method for determining apramycin in swine kidney t issue is described. Apramycin is extracted from tissue with basic methanol and purified by ion-pair extraction. By using an automated derivatization a nd injection procedure, the purified extract is derivatized with o-phthalde hyde, separated on a C-18 column, and detected with a fluorescence detector . For fortified kidney samples, between-run coefficients of variation range d from 4.8 to 7.1% at 1.00 ppm and from 9.6 to 14.3% at 0.50 ppm. Recoverie s ranged from 76 to 86%. Standard curves were linear over the range 10-100 ng/mL.