Impurity control in liquid lithium loop for IFMIF target facility

Citation
Y. Kato et al., Impurity control in liquid lithium loop for IFMIF target facility, J NUCL MAT, 263, 1998, pp. 394-399
Citations number
6
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science","Nuclear Emgineering
Journal title
JOURNAL OF NUCLEAR MATERIALS
ISSN journal
00223115 → ACNP
Volume
263
Year of publication
1998
Part
A
Pages
394 - 399
Database
ISI
SICI code
0022-3115(199810)263:<394:ICILLL>2.0.ZU;2-Y
Abstract
In the IFMIF Lithium target system, the total lithium inventory is about 21 m(3) and the impurities in the lithium are controlled by a cold trap and a hot trap. From the safety standpoint, the control of tritium and beryllium -7 concentration in the lithium is the most important issue. Both elements are to be controlled by a cold trap. As an option for the tritium, a hot tr ap is also considered. Other impurities such as oxygen, nitrogen and carbon which will affect the compatibility of lithium and loop materials are also controlled by the cold and hot traps to an acceptable level, A swamping me thod to control the tritium concentration is analyzed. (C) 1998 Published b y Elsevier Science B.V. All rights reserved.