Diametral strain-controlled push-pull fatigue tests with zero mean strain w
ere carried out with miniaturized hourglass shaped specimens of an austenit
ic stainless steel in solution annealed condition at room temperature. The
specimens had a diameter of 1.25 mm at the minimum cross section and a tota
l length of 25.4 mm. The number of cycles to failure (N-f) was equal to or
slightly greater than that obtained with standard size specimens. N-f was a
lso revealed to be rather insensitive to the specimen load axis offset, ind
icating that the requirement of the specimen alignment to the load axis was
not very severe for the miniaturized specimen. (C) 1998 Published by Elsev
ier Science B.V. All rights reserved.