M. Ceretti et al., High-temperature residual strain measurements, using neutron diffraction, in brazed Cu/CFC graphite divertor structures, J NUCL MAT, 263, 1998, pp. 1005-1009
This work presents a study of residual strain evolution in a three layer ca
stelled mock-up for ITER obtained brazing carbon fibre composite (CFC) grap
hite with dispersion strengthened Cu (and with a GLIDCOP interlayer). Neutr
on diffraction measurements were carried out, on graphite at 30 degrees C,
300 degrees C and 600 degrees C and on dispersion strengthened (DS) Cu at 6
00 degrees C. For each material, the reference, unstrained value of the lat
tice parameter was obtained by measuring a powder of the same material at t
he same temperatures. While in DS Cu negligible strain values are found at
high temperature, a more complicated evolution of the strains is observed i
n CFC graphite relating to sample geometry. (C) 1998 Elsevier Science B.V.
All rights reserved.