High-temperature residual strain measurements, using neutron diffraction, in brazed Cu/CFC graphite divertor structures

Citation
M. Ceretti et al., High-temperature residual strain measurements, using neutron diffraction, in brazed Cu/CFC graphite divertor structures, J NUCL MAT, 263, 1998, pp. 1005-1009
Citations number
16
Categorie Soggetti
Apllied Physucs/Condensed Matter/Materiales Science","Nuclear Emgineering
Journal title
JOURNAL OF NUCLEAR MATERIALS
ISSN journal
00223115 → ACNP
Volume
263
Year of publication
1998
Part
A
Pages
1005 - 1009
Database
ISI
SICI code
0022-3115(199810)263:<1005:HRSMUN>2.0.ZU;2-X
Abstract
This work presents a study of residual strain evolution in a three layer ca stelled mock-up for ITER obtained brazing carbon fibre composite (CFC) grap hite with dispersion strengthened Cu (and with a GLIDCOP interlayer). Neutr on diffraction measurements were carried out, on graphite at 30 degrees C, 300 degrees C and 600 degrees C and on dispersion strengthened (DS) Cu at 6 00 degrees C. For each material, the reference, unstrained value of the lat tice parameter was obtained by measuring a powder of the same material at t he same temperatures. While in DS Cu negligible strain values are found at high temperature, a more complicated evolution of the strains is observed i n CFC graphite relating to sample geometry. (C) 1998 Elsevier Science B.V. All rights reserved.