Comparison of ultrasound effects in different reactors at 20 kHz

Citation
F. Faid et al., Comparison of ultrasound effects in different reactors at 20 kHz, ULTRASON SO, 5(3), 1998, pp. 119-124
Citations number
16
Categorie Soggetti
Chemistry
Journal title
ULTRASONICS SONOCHEMISTRY
ISSN journal
13504177 → ACNP
Volume
5
Issue
3
Year of publication
1998
Pages
119 - 124
Database
ISI
SICI code
1350-4177(199811)5:3<119:COUEID>2.0.ZU;2-M
Abstract
To compare the performances of three power ultrasonic devices at 20 kHz: a horn, a cup horn and a tube, the local intensity distributions of local eff ects of cavitation have been investigated. The sensor is an electrochemical probe, measuring the solid-liquid mass transfer rate, related to the cavit ation intensity. The axial and radial profiles of mass transfer coefficient s have been investigated in three devices, at various power inputs. In all these equipments very strong heterogeneities have been characterized, wheth er a standing wave appears or not. (C) 1998 Elsevier Science B.V. All right s reserved.