Precise representation of geometry and energy is essential to properly acco
unt for self-shielding effects in tungsten. Up to a factor of 7 overestimat
ion of tungsten decay heat results from homogenization of tungsten and wate
r cooled heat sink behind it and using non-self-shielded cross sections in
the activation calculations. To correctly estimate tungsten decay heat, 3-D
continuous energy Monte Carlo calculations with proper layered heterogeneo
us modeling should be used to calculate the spectra and reaction rates or e
ffective self-shielded cross sections to be adopted in the activation calcu
lations.