EVALUATION OF MOTOR POWER-CABLES FOR PWM AC DRIVES

Citation
Jm. Bentley et Pj. Link, EVALUATION OF MOTOR POWER-CABLES FOR PWM AC DRIVES, IEEE transactions on industry applications, 33(2), 1997, pp. 342-358
Citations number
12
Categorie Soggetti
Engineering,"Engineering, Eletrical & Electronic
ISSN journal
00939994
Volume
33
Issue
2
Year of publication
1997
Pages
342 - 358
Database
ISI
SICI code
0093-9994(1997)33:2<342:EOMPFP>2.0.ZU;2-P
Abstract
Three-phase power cables installed between the inverter and motor of a s drive systems have been mostly ignored in the years since ac drives have became widely accepted in industrial applications, However, cable characteristics have become quite critical with the advent of faster inverter switching times, which have decreased by a factor of perhaps 20:1 in the last ten years, This paper describes the present areas of concern with regard to the power cabling, as well as a test program to quantitatively evaluate cable-related remedies for these problematic areas, a relative ranking of test results is developed comparing the e ight cable types tested, Cable connector considerations are examined, together with interconnection of the cable shield, or sheath, and the NEC ground circuits are discussed in light of the test results and rec ommendations presented, Cable voltage ratings are discussed and recomm endations made, A final cable total performance comparison, including installation factors, summarizes the paper.