Reaction rate method for determination of nitrite by applying a stopped-flow technique

Citation
Ia. Pettas et al., Reaction rate method for determination of nitrite by applying a stopped-flow technique, ANALYT CHIM, 376(3), 1998, pp. 331-337
Citations number
15
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences
Journal title
ANALYTICA CHIMICA ACTA
ISSN journal
00032670 → ACNP
Volume
376
Issue
3
Year of publication
1998
Pages
331 - 337
Database
ISI
SICI code
0003-2670(199812)376:3<331:RRMFDO>2.0.ZU;2-C
Abstract
A rapid, sensitive, and accurate method for the determination of nitrite is described based on its catalytic effect on the reaction between thymol blu e and bromate in the presence of sulphuric acid. The optimum conditions for various parameters on which the rate of the reaction depends, such as temp erature and pH, were investigated. The kinetics of the reaction were establ ished by monitoring the decrease in absorbance of thymol blue at 543 nm by a stopped-flow technique. The linear calibration range for low concentratio n of nitrite ions was found to be 5-80 ng ml(-1)with a 2 sigma limit of det ection of 4.5 ng ml(-1). The calibration for higher concentrations of nitri te was linear from 0.1 to 25 mu g ml(-1). The interference effect of severa l ions was investigated. The method can be extended to the determination of nitrate after their reduction to nitrite. (C) 1998 Elsevier Science B.V. A ll rights reserved.