The purpose of the present measurements was to determine neutron spect
ra outside the shielding of high energy electron accelerators, with a
special emphasis on the high energy (>20 MeV) portion of the spectra.
The spectrometer system used consists of a standard set of Bonner sphe
res augmented by a custom made 30.48 cm (12'') sphere with a 1 cm inne
r layer of lead, which increases its response in the high energy regio
n. The system was further complemented by a plastic scintillator used
for the measurement of C-11 activation. A pair of rem meters was also
used: one standard Anderson-Braun, and one with an inner layer of lead
which has an extended high energy response. Measured spectra and rele
vant dosimetric quantities outside shielding at three different electr
on beam energies are presented.