Ca. Varotsos et al., Total ozone measurements over Athens: intercomparison between Dobson, TOMS(version 6) and SBUV measurements, INT J REMOT, 19(17), 1998, pp. 3327-3333
An intercomparison of total ozone observations made with Solar Backscatter
Ultraviolet (SBUV) experiment, the Total Ozone Mapping Spectrometer (TOMS),
flown on the Nimbus-7 satellite, and the Dobson spectrophotometer installe
d at Athens, Greece, is presented in order to examine their precision and a
ccuracy. The results show that there is a very good agreement between the c
ompared datasets corresponding to a regression line coefficient interval of
0.932-0.934.