Wall loads were measured in a model bin 2.44 m in diameter and 7.3 m tall e
quipped with a bottom unloading wall flume. The results were then compared
to the wall loads measured during unloading of this same bin without the fl
ume. During most of unloading the wall loads measured when using the flume
were smaller than those during filling. However, at the onset of discharge
a load spike was observed prior to the formation of the funnel-flow dischar
ge pattern. Wall moments in the direction of the flume were observed to occ
ur which were three times as large as those measured during centric unloadi
ng.