Er. Meinders et al., Measurement and application of an infrared image restoration filter to improve the accuracy of surface temperature measurements of cubes, EXP FLUID, 26(1-2), 1999, pp. 86-96
This paper presents the experimental investigation of the application of an
image restoration technique aimed at improving the accuracy of infrared su
rface temperature measurements of cubes placed in a vertical channel flow.
These cubes, used to determine distributions of the local heal transfer coe
fficient, show large spatial temperature gradients. The image restoration t
echnique, developed to correct the spatial image degradation, is based on t
he two-dimensional Optical Transfer Function constructed from line spread f
unctions (LSF). The benefit of the application of the infrared image restor
ation technique is verified with temperature measurements acquired from a s
econd independent technique.