Improper storage is one factor than can precipitate failures in electronic
products, especially in a hostile environment. In this case study, failures
were observed in the propulsion logic modules on trains that were stored i
n Taiwan for nearly 3 years.
Failure analysis was conducted to identify the root cause of IC failures. E
xternal inspection showed that contaminants were deposited on the external
lead frames. The failure modes in the ceramic packages were observed to be
open metallization, although both visual inspection and scanning electron m
icroscopy revealed no trace of corrosion or damage to the die surface. Inte
rnal inspection of the plastic dual-in-line packages (P-DIP)s revealed dama
ge to the metallization and glassivation on the die surfaces, and contamina
nts were found at the failure sites. The major failure mechanism was ionic
corrosion, probably caused by high humidity as well as the presence of cont
aminants in the storage environment or from the device themselves. (C) 1998
Published by Elsevier Science Ltd. All rights reserved.