The effect, of external pressure oil the plasma parameters in an ablative c
apillary discharge is studied. A comparison between the plasma parameters i
n such a situation and those obtained when the pressure outside the capilla
ry is negligibly small was performed. The theoretically predicted results f
or the electrical characteristics of the discharge were compared to the cor
responding experimentally obtained values, anti were found to he in good ag
reement.