USE OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PHOTODIODE-ARRAY UV DETECTION FOR THE CREATION OF A 600-COMPOUND LIBRARY - APPLICATION TO FORENSIC TOXICOLOGY
Y. Gaillard et G. Pepin, USE OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PHOTODIODE-ARRAY UV DETECTION FOR THE CREATION OF A 600-COMPOUND LIBRARY - APPLICATION TO FORENSIC TOXICOLOGY, Journal of chromatography, 763(1-2), 1997, pp. 149-163
Citations number
17
Categorie Soggetti
Chemistry Analytical","Biochemical Research Methods
A high-performance liquid chromatographic method is described with pho
todiode array detection for systematic toxicological analysis in human
blood and urine, After a single step liquid-liquid extraction using T
oxi-Tube A, drugs are analyzed with a multi step gradient (phosphate p
H 3.8-acetonitrile) on a Symmetry C-8 5-mu m column (250 mm x 4.6 mm I
.D.) (Waters), operated at 30 degrees C. The flow-rate is varied durin
g the run from 1 ml/min to 1.5 ml/min. Full UV spectra are recorded on
-line during the 28 min chromatographic run. Enhanced performances for
drug detection are obtained with this method due to (a) reduction of
peak-tailing for basic drugs, (b) lower identification limits, (c) mor
e stable retention times and (d) larger number of referenced drugs (68
4 spectrum registered). Application of real samples has been demonstra
ted.