The use of rectus abdominis sheath for wrapping of the hydroxyapatite orbital implants

Authors
Citation
Scs. Kao et S. Chen, The use of rectus abdominis sheath for wrapping of the hydroxyapatite orbital implants, OPHTHAL SUR, 30(1), 1999, pp. 69-71
Citations number
7
Categorie Soggetti
Optalmology
Journal title
OPHTHALMIC SURGERY AND LASERS
ISSN journal
0022023X → ACNP
Volume
30
Issue
1
Year of publication
1999
Pages
69 - 71
Database
ISI
SICI code
0022-023X(199901)30:1<69:TUORAS>2.0.ZU;2-S
Abstract
Because of the decreasing availability of whole eye donation, the source of banked sclera is becoming less available. We used autogenous Rectus abdomi nis sheath (RAS) as an alternative to banked sclera in wrapping the hydroxy apatite (HA)orbital implant. Five anophthalmic patients were included in th is study from July 1994 to December 1997. Identical surgical methods were u sed in every case. The average follow-up time was 18.4 months. The motility associated with sheath-wrapped HA implants was excellent and good vascular ingrowth was found in each patient during peg drilling. The complications are minimal in all the cases. Use of RAS as wrapping material for HA orbita l implant has promising results. The RAS served as a practical substitute f or banked donor sclera.