E. Cereda et al., Comparison between self-field AC losses of a single-phase Bi-2223 cable measured by electric and calorimetric methods, PHYSICA C, 310(1-4), 1998, pp. 231-235
High-T-c power cables based on Bi-2223 tapes are under development worldwid
e. An important parameter for design and cost optimization is the AC loss e
xpected during 50/60 Hz operation. Its measurement can be affected by sever
al experimental problems that may alter the results. For this purpose, the
50 Hz losses of a 1.5 m long conductor, made by helically winding four laye
rs of Bi-2223 tapes, were measured simultaneously by electrical and calorim
etric methods in a wide range of currents up to 2 kA in order to investigat
e the reasons for possible discrepancies. The present, specifically designe
d, calorimetric system is not based on temperature distribution analysis bu
t on the measurement of the gas boil-off rate of the liquid nitrogen bath.
(C) 1998 Elsevier Science B.V. All rights reserved.