An array of Pt-tip microelectrodes for extracellular monitoring of activity of brain slices

Citation
P. Thiebaud et al., An array of Pt-tip microelectrodes for extracellular monitoring of activity of brain slices, BIOSENS BIO, 14(1), 1999, pp. 61-65
Citations number
21
Categorie Soggetti
Biotecnology & Applied Microbiology
Journal title
BIOSENSORS & BIOELECTRONICS
ISSN journal
09565663 → ACNP
Volume
14
Issue
1
Year of publication
1999
Pages
61 - 65
Database
ISI
SICI code
0956-5663(19990101)14:1<61:AAOPMF>2.0.ZU;2-0
Abstract
A microelectrode array (MEA) consisting of 34 silicon nitride passivated Pt -tip microelectrodes embedded on a perforated silicon substrate (porosity 3 5%) has been realized. The electrodes are 47 mu m high, of which only the t op 15 mu m are exposed Pt-tips having a curvature of 0.5 mu m. The MEA is i ntended for extracellular recordings of brain slices in vitro. Here we repo rt the fabrication, characterization and initial electrophysiological evalu ation of the first generation of Pt-tip MEAs. (C) 1999 Elsevier Science S.A . All rights reserved.