Research of porous coating influence on heat exchange crisis in circular cooling channels at one-sided loading

Citation
Va. Divavin et Sa. Grigoriev, Research of porous coating influence on heat exchange crisis in circular cooling channels at one-sided loading, PLASMA D OP, 6(1-3), 1998, pp. 45-53
Citations number
5
Categorie Soggetti
Nuclear Emgineering
Journal title
PLASMA DEVICES AND OPERATIONS
ISSN journal
10519998 → ACNP
Volume
6
Issue
1-3
Year of publication
1998
Pages
45 - 53
Database
ISI
SICI code
1051-9998(1998)6:1-3<45:ROPCIO>2.0.ZU;2-V
Abstract
Test data on the Ultimate Heat Flux investigation at a heat loading typical for the ITER Divertor are presented. It is determined that using of techno logy of the Porous Coating deposition to the cooling channel surface leads to a significant increase of the Ultimate Heat Flux value. Before-crisis and pre-crisis temperature state calculation results for one- sided loaded rectangular meek-ups with tubular cooling channels are given. Two alternative conceptions (optimistic and pessimistic) were used in the c alculations. Water flow rate influence on the mock-up temperature level was investigated.