From the results of investigations at full-scale and pilot plants, it has b
een found that with 'usual' parameters the ASM1 is only valid for a small r
ange of SRT as well as of oxic reactor section (V-OX/V) To make ASM1 applic
able to a wider range of SRT the very slowly biodegradable particulate orga
nic matter has to be taken into consideration. This fraction can be interpr
eted as part of the 'heterotrophic biomass' X-B,X-H which requires modifica
tion of the values for the 'heterotrophic decay rate' b(H) and for the frac
tion of X-I in the influent. In order to distinguish between 'active hetero
trophic biomass' (X-B,X-H) and the very slowly biodegradable substrate it s
eems to be useful to inkoduce the latter mass fraction as a new model compo
nent (X-V) into the ASM1. This extended simulation model has given reasonab
le results for different activated sludge systems. (C) 1999 IAWQ Published
by Elsevier Science Ltd. All rights reserved.